Split Type DC Inverter Heat Pump

1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)

DC inverter heat pump

Split Type DC Inverter Heat Pump

Blueway DC inverter Heat Pump, with the advanced Split type DC inverter technology, inverter air to water heat pump can save you 65% heating cost compare with the traditional heating device like gas/fuel boiler and electrical heater. It works perfectly with the radiator and floor heater to provide you a comfortable living environment even in very cold winter. It is one of the best heating devices available today.

Split Type DC Inverter Heat Pump FEATURES:

* Twin rotary compressor with inverter control – DC inverter technology control the heat pump output according to the household’s energy requirements. Low waste of the power!
* Economical and high efficiency – advanced heat pump technology can reduce your heating costs by 65% compare with the traditional heating elements
* R410a refrigerant, environmentally friendly – Green energy, no CO2 emissions
* Advanced controlling – it is extremely easy to control the heat pump because of the intelligent controller and LCD displaying.
* Safe operation with multi-protections – Overheating protection, high compressor discharge pressure, high compressor temperature, low pressure protection… make the unit running safely.
* Electronic Expansion Value allows the accurate refrigerant go through under different working conditions. So it ensures that the heat pump can work with high efficiency to provide enough cooling/heating capacity in any conditions.
* Hydrophilic coating air exchanger and SWEP plate heat exchanger all available
* 4-way valve to ensure reliable defrosting function
* Relatively low initial investment, easy and convenient for installation and maintenance
Warranty:
* CE & RoHS approval.
* 1 years warranty on the whole unit
* 1% spare parts free of charge for maintenance.
Support:
Blueway is capable of manufacturing and supplying even the largest liquid heating and cooling requirement for applications. We are looking forward to find potential partner all over the world to cooperate together. We are insisting on the strategy of: “Client service firstly and continuous development”, we will offer better product with best service to all the customers. For clients’ special design requirement, if the annual order quantity is above: 300pcs. We can offer one special design for you exclusively.
OPTIONAL:
* Galvanized metal cabinet or stainless steel cabinet all available

Split Type DC Inverter Heat Pump Application Installation

Split-inverter-heat-pump-1

Split Type DC Inverter Heat Pump Connection Diagram

Split-inverter-heat-pump-2

Features & Highlights

  • Residential-pool-heat-pump-3Silver welding
    Blueway welding technology let the units system more reliable; in most probably it will avoid the refrigerant leakage
  • Residential-pool-heat-pump-4Smart control
    The units apply intelligent control system: Micro processor based digital controller with LCD display
  • Residential-pool-heat-pump-7High efficiency eco-friendly refrigerant, without ozone depletion
  • Commerial-pool-heat-pump-3Hot gas defrosting
    Blueway adopt “SAGINOMAMIYA” four way valve for the defrosting system. It could defrost itself intelligently & efficiently.
  • Commerial-pool-heat-pump-4EEV technology
    The Electronic Expansion Valve technology Blueway adopt is a very unique and advanced technology. Through intelligent control of refrigerant flow, the use of an electronic expansion valve(EEV) has a number of advantages for the system.
    1. The EEV increase the heating output and the COP
    2. The EEV improves the overall operational reliability
    3. The EEV extends the lifespan of the compressor
  • Commerial-pool-heat-pump-5DC Inverter, Energy Efficiency
    DC inverter tecnology makes the unit get higher efficiency and save more than 30% energy consumption in annual running.
  • Commerial-pool-heat-pump-6Famous brand plate heat exchanger ensure the high efficiency and reliability of the whole heat pump system.
  • Commerial-pool-heat-pump-7High efficiency eco-friendly refrigerant, without ozone depletion
Split DC inverter heat pump specification
Model IHP-6S IHP-8S IHP-11S IHP14S IHP-16S
Power supply V/Hz/Ph 220-240/50/1 380-415/50/3
Norminal capacity Heating KW 6.20 8.10 11.25 14.51 16.10
Cooling KW 6.00 7.00 10.50 12.50 13.10
Power input Heating KW 1.44 1.92 2.60 3.41 3.88
Cooling KW 2.22 2.61 3.86 4.79 4.87
COP 4.30 4.21 4.32 4.25 4.15
EER 2.7 2.68 2.72 2.61 2.69
Outdoor Unit
Working ambient temperature range °C -20~43
Compressor Type Rotary Rotary Twin-Rotary Scroll
Refrigerant R410A
Sound power level dB(A) 61 62 64 64 66
Sound pressure level dB(A) 48 49 51 51 52
Air flow volume m³/hour 2000 3300 6000 6000 7000
Rated cureent A 10 12 17 21 7
Maximum cureent A 15 17 25 30 10
Dimension: WxHxD Net mm 870*700*310 900*835*330 1050*1260*420 1044*1415*420
Packing mm 990*780*410 1030*940*440 1111*1350*450 1111*1525*450
Weight Net 58 65 95 98 113
Gross 64 80 103 106 122
Indoor Unit
Maximum leaving water temperature
without using back-up heater
°C 55
Major
components
buit-in
Expansion
vessel
Volume liter 10 10 10 10 10
Max. water
pressure
Bar 3 3 3 3 3
Pre pressure Bar 1 1 1 1 1
Water Pump pressure
head:
Min./Max.
meter 5/8 5/8 5/8 5/8 5/8
Heat
exchanger
Type SUS 316 Plate
Water flow
rate
m³/h 1.6 2.1 2.9 3.7 4.2
Water
volume
liter 4.48 5.6 2.8 3.2 4
Buffer tank Volume liter 15 15 20 20 20
Max.
pressure
Bar 2 2 2 2 2
Factory
mounted
back up
heater
Capacity KW 4 (2*2) 6 (2*3)
Capacity step 2 3
Rated
current
A 18.18 27.27 15.79
Pressure
gauge
Water yes
Refrigerant yes
Water Flow switch yes
Safty valve yes
Air purge valve yes
Motorized 3-way valve Optional
Dimension: WxHxD Net mm 508*862*375
Packing mm 568*902*415
Weight Net 65 66 67 68 69
Gross 69 70 71 72 73
Installtion connection
Refrigerant
piping
Liquid Diameter (OD) in 1/4 3/8 3/8 1/2 1/2
Gas Diameter (OD) in 1/2 5/8 5/8 3/4 3/4
Length Standard m 4 4 5 5 5
Max. m 20 20 30 30 30
Installation
height
difference
Max. m 12 12 20 20 20
Refrigerant
charge
R410A charge gram 2700 3400 3900 4300 4700
additional g/m 70 80 80 90 90
Water piping
connection
Inlet diameter in. 1 1 1/4 1 1/4 1 1/2 1 1/2
Outlet diameter in. 1 1 1/4 1 1/4 1 1/2 1 1/2
Container loading 20′/40′/40HC sets

Notes:
The above capacities and power inputs are based on the following conditions:
– Heating: Outdoor temperature DB/WB 7°C/6°C, Inlet/Leaving water temperature 30°C/35°C;
– Cooling: Outdoor temperature DB/WB 35°C/24°C, Inlet/Leaving water temperature 12°C/7°C;
Blueway reserves that rights to modify the above specifications without notice.